SECTION
1. FUNCTIONAL
MODES
1.1.3
TABLE PRIORITY/INTERRUPTS
Table
1
execution has
priority
over
Table 2. lf
Table
2 is being
executed when
it is time to
execute
Table 1, Table
2 will
be interrupted.
After
Table 1 is
completed, Table
2 resumes
at
the
point
of
interruption.
lf
the
execution interval
of
Table
2
coincides
with
Table
1, Table 1
will
be executed first,
followed
by Table
2.
Interrupts
by Table
1
are
not
allowed
in
the
middle
of
a measurement
or while
output
to
Final
Storage is in
process
(the
Output Flag, flag
0, is
set high). The
interrupt occurs
as soon
as
the
measurement
is
completed or flag 0 is
set
low.
1.1.4 COMPILING
A PROGRAM
When
a
program
is first entered,
or if
any
changes
are
made
in the
*1
,*2,*3,
*4, *A,
or
*C
Modes,
the
program
must
be
compiled before
it
starts
running. The
compile function
checks for
programming
errors
and optimizes
program
information
for
execution. lf
errors are detected,
the appropriate error
codes are indicated
on the
Display
(Section
3.10). The
compile
function
is
executed
when the
*0
,
*6,
or
*B
Modes are
entered
and
prior
to saving a
program
listing in
the
*D
Mode.
The
compile
function
is only
executed
a{ter
a
program
change has been
made;
any subsequent use
of any
of
these
Modes
does not cause compiling.
When
the
*0, *B,
or
*D
Mode is
used to compile,
all output
ports
and flags are set low, the
timer
(lnstruction
26)
is reset, and
data values
contained in Input
and Intermediate
Storage are
RESET
TO ZERO.
When
the
*6
Mode is
used to compile data
values
contained in Input Storage,
the state
of
flags,
control
ports,
and the timer
are
UNALTERED.
Compiling always
zeros
Intermediate
Storage.
1.2
SETTING AND
DISPLAYING THE
CLOCK.
*5
MODE
The
"5 Mode is used
to display
time or change
the
year,
day
of
year,
or
time. When
*5
is
pressed,
the
current
time
is
displayed. The
time
parameters
displayed
in the
*5
Mode are
given
in
Table
1.2-1.
1-2
The
21X
powers-up
with
hours
and
minutes
set
to 0 and the day
and
year
set for the
date that
the PROMs were
first
released
by Campbell
Scientific. To
set
the
year,
day, or time, enter
the
*5
Mode
and advance to
display the
appropriate value.
Key in the
desired number
and
enter the value by
pressing
A.
When
a
value
for
hours
and
minutes
is
entered, the
seconds are set
to zero and current time is
again displayed.,
To exit the
"5
Mode,
press
*.
When
the time is
changed, a
partial
recompile i
done
automatically to
resynchronize
program
execution
with
real
time.
The resynchronization
process
can change the interval
of a
pulse
rate
measurements
for one execution
interval
as
explained in the PULSE
COUNT
Instruction
3
Section 9.
TABLE 1.2-1.
Sequence
of
Time
in
*5
Mode
Key
*5
A
A
A
Display
ID:DATA
:HH:MM:SS
05:XX
05:XXXX
05:HH:MM:
Description
Display
current time
Display/enter
year
Display/enter day
of
hours:
1.3
DISPLAYING AND ALTERING IN
MEMORY
OR FLAGS
.
*6
MODE
The
*6
Mode
is used to display
or
change lnput
Storage values
and
to toggle
and
display
user
flags. lf
the
*6
Mode
is
entered
immediately
following
any changes in
program
tables
or the
*4
Mode, the
programs
will
be compiled and
execution will begin.
When
the
*6
Mode
is
used
to compile data
values
contained in Input
Storage,
the
state of
flags,
control
ports,
and the timer are
UNALTERED.
Compiling always
zeros
Intermediate
Storage.
Vedere la pagina 27