01:
02:
03:
SECTION
9.
INPUT/OUTPUT
INSTRUCTIONS
lf the
SW8A does not
respond,
-99999
will
be
loaded
into input locations.
Modules
which do
not respond
when addressed
by
the datalogger
may be wired
or addressed incorrectly.
Verify
that the
address specified in Parameter
2
corresponds
to
the
jumper
setting
and that all
connections
are correct
and
secure.
See the
SDM-SW8A Manual for
examples.
PARAM.
DATA
NUMBER
TYPE
DESCRIPTION
r**
104 SDM-CD16
..*
The
SDM-CD16
Control
Port
Expansion
has
16 digitalcontrol
ports
with
drivers. Each
port
can be controlled by
a datalogger or
controlled manually with
an override toggle
switch. Each
port
can
be thought of as
a switch
to
ground;
closed
when
active, open when
inactive. The
primary{unction
is
to activate DC
powered
external
relays,
solenoids, or resistive
loads under datalogger
control.
This
instruction
is not
in
all PROM options.
The
SDM-CD16 is a synchronously addressed
datalogger
peripheral.
.Datalogger
control
ports
1, 2
and
3 are
used
to address the
SDM-CD16
then
clock
out
the
desired
state
of each
of
the
16
control
ports.
Up
to 16
SDM-CD16's may
be
addressed, making it
possible
to control
a
maximum of 256
ports
from
the
first
three
datalogger control
ports.
For
each
Rep, the
16
ports
of the addressed
SDM-CD16
are set
according to 16
sequential
input locations
starting
at
the
input location
specified in
parameter
3. Any non-zero
value
stored
in
an input location activates
(connects
ground)
the
associated SDM-CD16
port.
A
value of zero
(0)
deactivates the
port (open
circuit).
For
example, assuming 2 Reps
and
a
starting
input
location of 33,
OUTPUT
1 through
16
of the
first
SDM-CD16 are set according
to
Input
Locations 33 through 48, and OUTPUT 1
through
16
of
the second SDM-CD16 are set
according to Input Location
49
through
64. See
the
SDM-CD16 manualfor detailed
instructions
and
examples.
PARAM.
DATA
NUMBER TYPE DESCRIPTION
Reps
(#
of
CD16
sequentially
addressed)
Starting Address
(base
4:
00..33)
Starting
input location
2
Number
of Channels
2
Module Address
(00..33)
2
Function
Option
(O=State,
1=Duty
2=Counts,
3=Signature)
O4: 2
SDM-SW8A
Starting
Channel
(1..8)
05:
4
Starting input location for
results
FP
Mult
FP
Offset
***
103
SDM-AO4
*"*
Instruction
103
is
used
to
activate
a SDM-AO4 4
Channel Continuous
Analog Output Module
connected
to
ports
C1, C2,
and
C3. This
instruction
is not
in
all PROM options.
There
are 4
analog
voltage
outputs
per
SDM-
AO4. The
output voltages in millivolts must
be
stored
in
4
adjacent
input
locations starting with
the
location
entered
in
parameter
4. Four reps
are
required
for each
SDM-AO4. Every 4 reps
another device at the next higher
address is
selected.
PARAM.
DATA
NUMBER
TYPE DESCRIPTION
2
Reps
(#
of outputs)
1
=
SDM-A04
2
Address
(Base
4)
4
Starting
input
location
C1
is Data
line
C2
is
Clk/Hand
Shake line
C3
is
SDE
(Enable)
line
06:
07:
01
02
03
2
2
4
1
2
3
9-14