Campbell CS225 Manuale delle Istruzioni Pagina 6

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 5
CS225 Temperature String
3
3. Initial Inspection
x Upon receipt of the CS225, inspect the packaging and contents for
damage. File any damage claims with the shipping company. Immediately
check package contents against the shipping documentation. Contact
Campbell Scientific about any discrepancies.
x The model number and cable length are printed on a label at the
connection end of the cable. Check this information against the shipping
documents to ensure the expected product and cable length are received.
x The CS225 is shipped with a SGB3, FIN4COND cable, and a
ResourceDVD.
x
4. Overview
The CS225 temperature string makes use of digital sensor technology allowing
for a simple 3-wire integration. The CS225 consists of an arrangement of
overmolded temperature points mounted in a rugged steel reinforced cable.
Each CS225 is manufactured to the client’s specific requirements.
The CS225 is suited for a wide variety of applications and environments that
require temperature profiling. The completely sealed cable assembly permits
the CS225 to be buried, submerged or integrated directly into structures.
Examples of some applications include temperature profiling in boreholes,
soils, water, and frost & permafrost monitoring.
The purpose of the SGB3 is to provide adequate surge protection for the CS225
Temperature String. The case of the SGB3 is suited for mounting to a back
plate with 1 inch on centre spacing.
5. Specifications
Features:
x Accurate and stable measurements
x Each sensor is individually addressed and referenced to its depth
x Low power consumption
x Digital SDI-12 output
Compatibility
Dataloggers: CR200(X) series
CR800 series
CR1000
CR3000
CR5000
CR510
CR10(X)
CR23X
Vedere la pagina 5
1 2 3 4 5 6 7 8 9 10 11 ... 24 25