CS225 Temperature String
7
without having to review the entire data set. The lifetime minimum and
maximum temperatures are used for maintenance and warranty records.
7.1. Wiring
Connections for the SGB3 and CS225 to Campbell Scientific dataloggers are
given in Table 7-1 and 7-2. When Short Cut for Windows software is used to
create the datalogger program, the sensor should be wired to the channels
shown on the wiring diagram created by Short Cut.
The SGB3 is required in order to protect against electrical surges. The SGB3
makes use of the included FIN4COND cable to make final connections to the
datalogger.
Figure 71 SGB3 3-Line Surge Protector
TABLE 7-1. CS225 Connection to
SGB3
Colour
Des
cription
CS225
Red
Power
L1
Green
SDI
-12
Signal
L2
Not Used
L3
Black
Power Ground
G
Clear
Shield
G