CS225 Temperature String
2
CS225 Temperature String
1. Introduction
The CS225 temperature string uses SDI-12 digital technology for simple
integration and reliability. The CS225 consists of an arrangement of
temperature sensors mounted in rugged steel reinforced cable. Temperature
points are overmolded to provide long-term protection in all mediums. Each
CS225 is manufactured to the client’s specific requirements and includes the
SGB3 to provide electrical surge protection.
Before using the CS225 please study:
x Section 2, Cautionary Statements
x Section 7.1, Wiring
More details are available in the remaining sections.
2. Cautionary Statements
x Although the CS225 is designed to be a rugged and reliable device for
field use, care should be taken when handling or moving it to avoid
damage.
x There are no user-serviceable parts and any attempt to disassemble the
device will void the warranty.
x The CS225 must be used in conjunction with the SGB3 in order to protect
against electrical surges.
Do not make tight bends near the temperature sensor(s). Doing
so has the potential to damage the sensor assembly. The
minimum bend radius at any sensor location is 6”/15 cm (12”/30
cm diameter). See image below.