Number 4250-2010
Revision 0.1
Date MAY 1996
Page 4 of 37
POST-FIELD INSPECTION CHECKLIST
HANDAR 540A/570A DCP
DCP S/N: ______________________________
Site: __________________________________
Date: _________________________________
Technician: ____________________________
DCP Model: ¨540A1 ¨540A2 ¨570A
Received for: ¨Annual Servicing ¨Unscheduled Maintenance
Reason for unscheduled maintenance _____________________________________________________
____________________________________________________________________________________
____________________________________________________________________________________
PHYSICAL INSPECTION - EXTERNAL
Describe "as returned" condition of the following:
DCP Case _____________________________________________________________________
Case Latches ___________________________________________________________________
Connectors/Contacts _____________________________________________________________
Display (570A Only) ______________________________________________________________
Door Seal ______________________________________________________________________
PHYSICAL INSPECTION - INTERNAL
Describe "as returned" condition of the following:
Power switch ¨On ¨Off
GOES Radio Channel 1 ¨900 ¨Other ______________________________________
GOES Radio Channel 2 ¨000 ¨Other ______________________________________
Circuit Boards, Hold Down Bracket, Connectors ________________________________________
Battery and Hold Down Bracket _____________________________________________________
Battery Voltage ________________ Volts
DCP TIMING CHECKS
Program in Memory ¨Yes ¨No
DCP ID [I] _________________________
DCP Time [J] __ __ : __ __ : __ __ WWV Time __ __ : __ __ : __ __
DCP Time to Next Scan [S] __ __ : __ __ : __ __
DCP Time to Next Transmit [T] __ __ : __ __ : __ __
DCP A/D CONVERTER CHECKS
Test Input
Ch. 1,2,3
DCP Channel # (Output)
CH1 CH2 CH3 CH4 CH5 CH10
0.000 Volts
4.950 Volts
Lab AT/RH
_______
_______
_______
_______
_______
_______
_______
_______
_______
_______
_______
_______
_______
_______
TRANSMISSION TEST
Forced Transmit RF Power Output _____________________ Watts
Figure 4-1. Post-Field Inspection Checklist - Handar 540A/570A DCP.