Installation, Operation and Maintainance of Automatic Meteorological Stations
4: 30 Then Do
39: If time is (P92)
1: 0 Minutes (Seconds --) into a
2: 5 Interval (same units as above)
3: 10 Set Output Flag High
40: Set Active Storage Area (P80)
1: 1 Final Storage Area 1
2: 300 Array ID
41: Sample (P70)
1: 1 Reps
2: 24 Loc [ LOGGER_ID ]
42: Real Time (P77)
1: 1220 Year,Day,Hour/Minute (midnight = 2400)
43: Sample (P70)
1: 1 Reps
2: 21 Loc [ FM_RAIN ]
44: End (P95)
;========= END OF RAINFALL SERIES OUTPUT INSTRUCTIONS ==========
;======= TO ACTIVATE AUTOMATIC DATA TRANSFER TO SM192 ==========
45: Serial Out (P96)
1: 71 SM192/SM716/CSM1
;DATALOGGER WILL CHECK EVERY FIVE MINUTES IF THE SM192 IS
;CONNECTED. IF NOT, IT WILL CONTINUE WITH THE NEXT STEP IN THE
;PROGRAM. IF CONNECTED, IT WILL TRANSFER ALL DATA IN THE FINAL
;STORAGE LOCATION AUTOMATICALLY TO THE SM192 WITHOUT ANY USER
;ACTION
;THIS COMMAND MAKES DATA TRANSFER FULLY AUTOMATIC
;======= END OF AUTOMATIC DATA TRANSFER ===================
;=============== CONTINUE WITH HOURLY OUTPUT ===============
46: If time is (P92)
1: 0 Minutes (Seconds --) into a
2: 60 Interval (same units as above)
3: 10 Set Output Flag High
47: Set Active Storage Area (P80)
1: 1 Final Storage Area 1
2: 200 Array ID
48: Sample (P70)