CSAT3 Three Dimensional Sonic Anemometer
29
TABLE 10-8. Wiring for Program Example 2
Description Color CR3000
SDM Data Green SDM-C1
SDM Clock White SDM-C2
SDM Enable Brown SDM-C3
Digital Ground Black G
SDM Signal Shield Clear G
Power Red +12 Vdc
Power Refernece Black G
Power Shield Clear G
EXAMPLE 2. Measuring the CSAT3 Using the SDM Output and a
CR23X Datalogger
;{CR23X}
;
;22 April 2001
;Copyright (c) 2001 Campbell Scientific, Inc. All rights reserved.
;Flags
;Flag 1 - Set low (default) to configure the CSAT3.
;Set high after CSAT3 is configured.
;() -> Compass coordinate system
;{} -> Right handed coordinate system
;
;
; theta (N)
; \ {-x}
; \ |
; CSAT3 \ |
; Transducers -> * |
; \ |
; \ |
; \ |
; (W) {-y} --------[ ]--------> {+y} (E)
; / |
; CSAT3 Block |
; |
; |
; v
; {+x}
; (S)
;