Campbell CR5000 Specifiche Pagina 127

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 238
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 126
7-1
Section 7. Measurement Instructions
7.1 Voltage Measurements
VoltDiff – Differential Voltage Measurement............................................. 7-3
VoltSE – Single-ended Voltage Measurement............................................ 7-3
7.2 Thermocouple Measurements
Measure the Output of Thermocouples and Convert to Temperature.
TCDiff – Differential Voltage Measurement of Thermocouple .................. 7-3
TCSE – Single-ended Voltage Measurement of Thermocouple.................. 7-4
Resistance Bridge Measurements
Bridge measurements combine an excitation with voltage measurements and
are used to measure sensors that change resistance in response to the
phenomenon being measured. These sensors include RTDS, thermistors,
potentiometers, strain gages, and pressure and force transducers.
7.3 Half Bridges
BrHalf – Half Bridge ................................................................................... 7-5
BrHalf3W – Three Wire Half Bridge .......................................................... 7-6
BrHalf4W – Four Wire Half Bridge............................................................ 7-6
7.4 Full Bridges
BrFull – Four Wire Full Bridge................................................................... 7-8
BrFull6W – Six Wire Full Bridge ............................................................... 7-9
7.5 Current Excitation
Resistance - Measures Resistance or Full Bridge with Current
Excitation........................................................................................... 7-11
7.6 Excitation / Continuous Analog Output
ExciteCAO - Sets the voltage of a Continuous Analog Output channel ... 7-13
ExciteI - Sets the specified current excitation channel to the current
specified............................................................................................. 7-14
ExciteV - Sets the specified switched voltage excitation channel to the
voltage specified................................................................................ 7-14
7.7 Self Measurements
Battery – Measures Battery Voltage or Current ........................................ 7-15
PanelTemp – (Used as a Reference for Thermocouple Measurements).... 7-15
Calibrate – Adjusts the Calibration for Analog Measurements................. 7-16
Vedere la pagina 126
1 2 ... 122 123 124 125 126 127 128 129 130 131 132 ... 237 238

Commenti su questo manuale

Nessun commento