SNOTEL GOES Manual Revision 2b - February 17, 2011 page 2 of 10
Micro Specialties, Inc. Wasilla, Alaska
Application Overview
msiDCSDecodeR2, provided by Micro Specialties, Inc (MSI), is designed to automate
the retrieval of GOES data reports from the National Environmental Satellite Data
Information System (NESDIS). These reports are presumed to have been generated by
a Campbell Scientific (CSI) data logger, and communicated through the GOES system
via a CSI TX412 data modem, or via a MicroComm GTX data modem. The application
can be configured to collect data from any number of GOES data platforms, and will
generate SNOTEL-compatible data messages intended to be automatically ingested by
SNOTEL. Data messages received from GOES, are automatically processed and
appended to an output text file named mbdata.txt. An external, cron-timed batch
process should be provided by NWCC, that will execute msiDCSdecode and feed the
content of mbdata.txt into the SNOTEL system. The batch process should rename
mbdata.txt to avoid having the application write to it while the batch is running, then
delete it when its content has been ingested into SNOTEL, as this application will never
delete or shrink mbdata.txt.
New Features and Revisions in Revision 2a 2/9/2010
Decodes all GTX sensor labels
Recognizes sensor values generated internal to the GTX such as the 'Clock',
'Battery', and values from the equation editor.
Understands GTX min/max/avg (NXG) flags
Will decode multiple values from a single GTX TPL Data Parameter entry
based on the 'Value Count' of that parameter.Allows more flexibility in site
group definitions.
Keeps track of successful data retrieval events to help prevent data gaps.
Exports most GOES procedures to new GOES python module.
New command line option to “fresh start” retrieval history.
New Features and Revisions in Revision 2b - 2/16/2011
ddsClient now logs only retrieve dates more recent than the last entry in the
log. This is intended to remove duplicate entries in the log.
Sorts the data records (mbdata.txt) by the data time stamp.
ddsClient now restricts attempted data retrieval to within 30 days of the
current date. Dates in the future are not allowed.
ddsClient now attempts to get data from the primary LRGS server, but will
switch to the backup server if the primary does not respond. The ddsClient
module now defines the IPs for the primary and backup LRGS servers.
Provides a command line option to use a specified LRGS (host) IP.