CS210 Enclosure Humidity Sensor
FIGURE 1. CS210 Installed on a CR1000
4. Wiring
Connections to Campbell Scientific dataloggers are given in Table 1 and
Figure 2. The probe is measured by a single-ended analog input channel.
TABLE 1. Datalogger Connections
Description
Color
CR200-series
CR800, CR850, CR1000,
CR3000, CR5000, CR9000(X),
CR10(X), CR500, CR510, CR23X
21X
Relative Humidity White Single-Ended Single-Ended Input Single-Ended
Input
Signal and Power
Reference
Clear G G
Power Black C2 5 V Control Port
Signal and Power Reference Clear
5 VDC Power Black
Signal White
FIGURE 2. CS210 Wiring