Campbell CS475 Manuale Utente Pagina 14

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 48
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 13
CS475, CS476, and CS477 Radar Water Level Sensor
4
CS475 CS476/CS477
1
2
Figure 4-1. Polarization markings (see Table 4-4 for label descriptions)
Table 4-4. Description of Polarization Markings Labels
Sensor Description
1 CS475 Polarization marks are designated by the mounting loop
screws.
2 CS476/CS477 Polarization mark is machine-tooled.
4.2 Step 2 — Do a False Echo Learn Command
Use the 25616, Adjustment/Display Module, or the terminal emulator in LoggerNet
or PC400 to do a Start False Echo Learn command followed by a Send Data
command (see Table 4-4). To start false echo learn, do the aXSFEL+nnn.nnn!
command (where nnn.nnn = the actual distance to the water) followed by the aD0!
(Send Data) command. Table 4-5 shows an example of the command and response.
Any echo occurring 0.5 m (1.6 ft) short of the distance you entered will be
considered noise.
Appendix B describes this command in further detail.
Vedere la pagina 13
1 2 ... 9 10 11 12 13 14 15 16 17 18 19 ... 47 48

Commenti su questo manuale

Nessun commento