21X MICROLOGGEROPERATOR’S MANUALREVISION: 3/96COPYRIGHT (c) 1984-1996 CAMPBELL SCIENTIFIC, INC.

Pagina 2

This is a blank page.

Pagina 3 - WARRANTY AND ASSISTANCE

SECTION 8. PROCESSING AND PROGRAM CONTROL EXAMPLES8-1413: P87 Beginning of Loop01: 0 Delay02: 512 Loop Count14: P86 Do01: 10 Set high Flag 0 (output)

Pagina 4

SECTION 8. PROCESSING AND PROGRAM CONTROL EXAMPLES8-15TABLE 8.8-4. FFT Bin Averaging Results from Simulated Ocean Buoy Wave DataBIN # FREQUENCY FFT*

Pagina 5 - OVERVIEW

SECTION 8. PROCESSING AND PROGRAM CONTROL EXAMPLES8-16When flag 2 is set the FFT is computed and theresults are sent to Final Storage.10: P91 If Flag

Pagina 6 - DATA RETRIEVAL/COMMUNICATION

SECTION 8. PROCESSING AND PROGRAM CONTROL EXAMPLES8-1711: P46 Z=X MOD F01: 4-- X Loc02: 360 F03: 4-- Z Loc :12: P48 Z=SIN(X)01: 4-- X Loc02: 8-- Z Lo

Pagina 7 - INSTRUCTIONS

SECTION 8. PROCESSING AND PROGRAM CONTROL EXAMPLES8-18This is a blank page.

Pagina 8 - APPENDICES

9-1SECTION 9. INPUT/OUTPUT INSTRUCTIONSTABLE 9-1. Input Voltage Ranges and CodesRange Code Full Scale RangeResolution*Slow Fast16.67ms 250µsInteg. I

Pagina 9 - SELECTED OPERATING DETAILS

SECTION 9. INPUT/OUTPUT INSTRUCTIONS9-2The count is incremented when the inputvoltage changes from below 1.5 volts toabove 3.5 volts. The maximum i

Pagina 10 - This is a blank page

SECTION 9. INPUT/OUTPUT INSTRUCTIONS9-3anywhere between one second too short toalmost twice as long. Pulses are not lost duringresynchronization so

Pagina 11 - CAUTIONARY NOTES

SECTION 9. INPUT/OUTPUT INSTRUCTIONS9-4PARAM. DATANUMBER TYPE DESCRIPTION01: 2 Repetitions02: 2 Range code03: 2 Input channel number forfirst measure

Pagina 12

SECTION 9. INPUT/OUTPUT INSTRUCTIONS9-5PARAM. DATANUMBER TYPE DESCRIPTION01: 2 Repetitions02: 2 Range code03: 2 Input channel number forfirst measure

Pagina 13 - 21X MICROLOGGER OVERVIEW

viCAUTIONARY NOTES1. Damage will occur to the analog inputcircuitry if voltages in excess of ±16 V areapplied for a sustained period. Voltages inexc

Pagina 14

SECTION 9. INPUT/OUTPUT INSTRUCTIONS9-6PARAM. DATANUMBER TYPE DESCRIPTION01: 2 Repetitions02: 2 Input channel number offirst measurement03: 2 Excitat

Pagina 15 - OV2. MEMORY AND PROGRAMMING

SECTION 9. INPUT/OUTPUT INSTRUCTIONS9-7TABLE 9-3. Thermocouple Type CodesCode Thermocouple Type X = 0 Normal MeasurementX1 T (copper - constantan) X

Pagina 16

SECTION 9. INPUT/OUTPUT INSTRUCTIONS9-8*** 17 TEMPERATURE OF INPUT PANEL ***FUNCTIONThis instruction measures the temperature indegrees Celsius of

Pagina 17

SECTION 9. INPUT/OUTPUT INSTRUCTIONS9-9*** 22 EXCITATION WITH DELAY ***FUNCTIONThis instruction is used in conjunction withothers for measuring a

Pagina 18 - OV3. PROGRAMMING THE 21X

SECTION 9. INPUT/OUTPUT INSTRUCTIONS9-10trigger when measurement goes from above thelimit to below it or when the digital trigger goesfrom high to lo

Pagina 19

SECTION 9. INPUT/OUTPUT INSTRUCTIONS9-11location number of Instruction 23 in the programtable. I2 divided by I3 is the multiplier and I4 theoffset (

Pagina 20 - OV4. PROGRAMMING EXAMPLES

SECTION 9. INPUT/OUTPUT INSTRUCTIONS9-12when donemeasuring.B Trigger option0 - Triggerimmediately1 - Trigger if abovelimit (high)2 - Trigger if below

Pagina 21

SECTION 9. INPUT/OUTPUT INSTRUCTIONS9-1302: 4 *Input configuration;channels 8,7,6,503: 4 *Input configuration;channels 4,3,2,104: 4 **Function; chann

Pagina 22

SECTION 9. INPUT/OUTPUT INSTRUCTIONS9-14If the SW8A does not respond, -99999 will beloaded into input locations. Modules which donot respond when ad

Pagina 23

10-1SECTION 10. PROCESSING INSTRUCTIONSTo facilitate cross referencing, parameterdescriptions are keyed [] to the values given onthe PROMPT SHEET. T

Pagina 24

This is a blank page.

Pagina 25

SECTION 10. PROCESSING INSTRUCTIONS10-2*** 36 X * Y ***FUNCTIONMultiply the value in location X by the value inlocation Y and place the result in

Pagina 26

SECTION 10. PROCESSING INSTRUCTIONS10-3*** 43 ABS(X) ***FUNCTIONTake the absolute value of the value in locationX and place the result in location

Pagina 27 - OV5. DATA RETRIEVAL OPTIONS

SECTION 10. PROCESSING INSTRUCTIONS10-4Parameter 3 cannot be entered as an indexedlocation within a loop (Instruction 87). To useInstruction 49 with

Pagina 28

SECTION 10. PROCESSING INSTRUCTIONS10-5PAR. DATANO. TYPE DESCRIPTION01: 4 Number of values to move02: 4 1st source location03: 2 Step of source04: 4

Pagina 29

SECTION 10. PROCESSING INSTRUCTIONS10-6PAR. DATANO. TYPE DESCRIPTION01: 4 Input location no. of atmosphericpressure in kilopascals[PRESSURE]02: 4 Inp

Pagina 30 - OV6. SPECIFICATIONS

SECTION 10. PROCESSING INSTRUCTIONS10-7amount of power at the different frequencies butdo not contain any phase information.If desired, the original

Pagina 31 - SECTION 1. FUNCTIONAL MODES

SECTION 10. PROCESSING INSTRUCTIONS10-8power spectral is output. Parameter 3 is equalto the log base 2 of A where A is the number ofbins to be avera

Pagina 32 - MEMORY OR FLAGS - *6 MODE

SECTION 10. PROCESSING INSTRUCTIONS10-9zero to peak amplitude or one quarter of thepeak to peak value of the sinusoidal signal.MAGNITUDE AND PHASE CO

Pagina 33

SECTION 10. PROCESSING INSTRUCTIONS10-10For example, given that the power spectra resultshows that the energy peak of a signal falls inbin 32 when it

Pagina 34 - 1.5 MEMORY ALLOCATION - *A

SECTION 10. PROCESSING INSTRUCTIONS10-11*** 61 INDIRECT INDEXED MOVE ***FUNCTIONMoves input data from location X to location Y,where X and Y are i

Pagina 35

OV-121X MICROLOGGER OVERVIEWThe 21X Micrologger combines precision measurement with processing and control capability in a singlebattery operated syst

Pagina 36 - 1.7 *C MODE -- SECURITY

SECTION 10. PROCESSING INSTRUCTIONS10-12TABLE 10-2. Maximum Number of Outputs and Output Order for K Input Values.(The output order flows from left

Pagina 37 - 1.8 *D MODE -- SAVE OR LOAD

SECTION 10. PROCESSING INSTRUCTIONS10-13The Input Processing phase is where new inputvalues are received, the necessary squares orcross products form

Pagina 38

SECTION 10. PROCESSING INSTRUCTIONS10-14N' is the number of input scans in the lastaveraging periodNT is the total number of input samplesproces

Pagina 39

11-1SECTION 11. OUTPUT PROCESSING INSTRUCTIONS*** 69 WIND VECTOR ***FUNCTIONInstruction 69 processes the primary variablesof wind speed and direct

Pagina 40

SECTION 11. OUTPUT PROCESSING INSTRUCTIONS11-2There are three Output Options, which specifythe values calculated.Option 0:Mean horizontal wind speed,

Pagina 41 - ARRAYS, AND MEMORY POINTERS

SECTION 11. OUTPUT PROCESSING INSTRUCTIONS11-3*** 71 AVERAGE ***FUNCTIONThis instruction stores the average value overthe given output interval for

Pagina 42 - RANGE LIMITS

SECTION 11. OUTPUT PROCESSING INSTRUCTIONS11-4(defined as the bin select value) is within aparticular subrange of the total specified range.The count

Pagina 43 - KEYBOARD/DISPLAY - *7 MODE

SECTION 11. OUTPUT PROCESSING INSTRUCTIONS11-5it is the first minute of the day. Similarly,entering 2 for the hour-minute code causes 2400instead of

Pagina 44

SECTION 11. OUTPUT PROCESSING INSTRUCTIONS11-6The output flag must be set each timeInstruction 80 is used. Instruction 80 mustdirectly follow the ins

Pagina 45 - 3.4 INDEXING INPUT LOCATIONS

SECTION 11. OUTPUT PROCESSING INSTRUCTIONS11-7More than one Rainflow Histogram can becalculated using the Repetitions parameter. Theswath of input da

Pagina 46 - 3.6 OUTPUT PROCESSING

21X MICROLOGGER OVERVIEWOV-2The 9-pin serial I/O port provides connection todata storage peripherals, such as theSM192/716 Storage Module or RC35 Cass

Pagina 47 - PROGRAM CONTROL

SECTION 11. OUTPUT PROCESSING INSTRUCTIONS11-8This is a blank page.

Pagina 48 - CONSTRUCTIONS

12-1SECTION 12. PROGRAM CONTROL INSTRUCTIONSTABLE 12-1. Flag DescriptionFlag 0 Output FlagFlag 1 to 8 User FlagsFlag 9 Intermediate Processing Disab

Pagina 49

SECTION 12. PROGRAM CONTROL INSTRUCTIONS12-2A delay of 0 means that there is no delaybetween passes through the loop. Eachtime the table is executed

Pagina 50 - EXECUTION TIME

SECTION 12. PROGRAM CONTROL INSTRUCTIONS12-3The user wants 1 hour averages of the vaporpressure calculated from the wet- and dry-bulbtemperatures of

Pagina 51

SECTION 12. PROGRAM CONTROL INSTRUCTIONS12-412: P89 If X<=>F01: 25 X Loc DAY02: 3 >=03: 6 F04: 31 Exit Loop if true13: P95 End14: P87 Beginn

Pagina 52

SECTION 12. PROGRAM CONTROL INSTRUCTIONS12-5the loop. Instruction 90 does not affect the loopcounter which still counts by 1.PAR. DATANO. TYPE DESCR

Pagina 53 - 3.10 ERROR CODES

SECTION 12. PROGRAM CONTROL INSTRUCTIONS12-6the start of the instructions to execute if the testcondition is false (Figure 3.8-1). The ElseInstructi

Pagina 54

SECTION 12. PROGRAM CONTROL INSTRUCTIONS12-7When either the DC112 or RF modem optionsare specified, the time limit on the call (without acorrect resp

Pagina 55 - INSTRUCTION 96, *4 MODE

SECTION 12. PROGRAM CONTROL INSTRUCTIONS12-8*** 98 SEND CHARACTER ***Instruction 98 is used to send a character to theprinter. The single paramet

Pagina 56 - OUTPUT - *8 AND *9 MODES

13-1SECTION 13. 21X MEASUREMENTS13.1 FAST AND SLOW MEASUREMENTSEQUENCEThe 21X makes voltage measurements byintegrating the input signal for a fixed

Pagina 57

21X MICROLOGGER OVERVIEWOV-3OV1.2 SWITCHED EXCITATION OUTPUTSThe first four numbered terminals on the lowerterminal strip are the SWITCHED EXCITATION

Pagina 58 - 4.3 CASSETTE TAPE OPTION

SECTION 13. 21X MEASUREMENTS13-2averaging the magnitude of the results from thetwo integrations and using the polarity from thefirst. An exception t

Pagina 59

SECTION 13. 21X MEASUREMENTS13-313.3 THE EFFECT OF SENSOR LEADLENGTH ON THE SIGNAL SETTLINGTIMEWhenever an analog input is switched into the21X meas

Pagina 60

SECTION 13. 21X MEASUREMENTS13-4NOTE: Since the peak transient, Veo,causes significant error only if it is severaltimes larger than the signal, Vso,

Pagina 61 - 4.5 PRINTER OUTPUT FORMATS

SECTION 13. 21X MEASUREMENTS13-5FIGURE 13.3-4. Wire ManufacturersCapacitance Specifications, CwDIELECTRIC ABSORPTIONThe dielectric absorption of ins

Pagina 62

SECTION 13. 21X MEASUREMENTS13-6Equation 13.3-12, -13 and -14 can be combinedto estimate the error directly in degrees atvarious directions and lead

Pagina 63 - COMMANDS

SECTION 13. 21X MEASUREMENTS13-7Equation 13.3-7 can be solved for the maximumlead length, L, permitted to maintain a specifiederror limit. Combining

Pagina 64

SECTION 13. 21X MEASUREMENTS13-8lead length. If the capacitive load exceeds 0.1µfd and the resistive load is negligible, Vx willoscillate about its

Pagina 65

SECTION 13. 21X MEASUREMENTS13-95. Use the 21X to measure the input settlingerror associated with a given configuration.For example, assume long lead

Pagina 66

SECTION 13. 21X MEASUREMENTS13-10FIGURE 13.3-7. Half Bridge Configurationfor YSI #44032 Thermistor Connected to 21XShowing: A) Large source resista

Pagina 67 - 6.1 PIN DESCRIPTION

SECTION 13. 21X MEASUREMENTS13-11polynomial approximation of the NBS TCcalibrations.13.4.1 ERROR ANALYSISThe error in the measurement of athermocoup

Pagina 68

21X MICROLOGGER OVERVIEWOV-4INPUT/OUTPUTINSTRUCTIONSSpecify the conversion of a sensor signal to adata value and store it in Input Storage.Programmabl

Pagina 69

SECTION 13. 21X MEASUREMENTS13-12THERMOCOUPLE LIMITS OF ERRORThe standard reference which liststhermocouple output voltage as a function oftemperatur

Pagina 70

SECTION 13. 21X MEASUREMENTS13-13error of about 0.6oC. In the environmentaltemperature range with voltage measured on anappropriate scale, error in

Pagina 71

SECTION 13. 21X MEASUREMENTS13-14and reference temperature polynomials areextremely small, and error in the voltagemeasurement is negligible.To illus

Pagina 72

SECTION 13. 21X MEASUREMENTS13-15FIGURE 13.4-2. Diagram of Junction BoxAn external reference junction box must beconstructed so that the entire term

Pagina 73 - A COMMON EXTERNAL POWER

SECTION 13. 21X MEASUREMENTS13-16FIGURE 13.5-1. Circuits Used with Instructions 4-9

Pagina 74 - JUNCTION

SECTION 13. 21X MEASUREMENTS13-17FIGURE 13.5-2. Excitation and MeasurementSequence for 4 Wire Full BridgeTABLE 13.5-1. Comparison of BridgeMeasurem

Pagina 75 - 7.5 107 TEMPERATURE PROBE

SECTION 13. 21X MEASUREMENTS13-18TABLE 13.5-2. Calculating Resistance Values from Bridge MeasurementInstr. Result Instr. Multiplier and Offset4XVR R

Pagina 76 - PHOTOCHOPPER OUTPUT

SECTION 13. 21X MEASUREMENTS13-1913.6 RESISTANCE MEASUREMENTSREQUIRING AC EXCITATIONSome resistive sensors require AC excitation.These include the 2

Pagina 77

SECTION 13. 21X MEASUREMENTS13-20This is a blank page.

Pagina 78

14-1SECTION 14. INSTALLATION AND MAINTENANCE14.1 PROTECTION FROM THEENVIRONMENTThe normal environmental variables of concernare temperature and moist

Pagina 79

21X MICROLOGGER OVERVIEWOV-53. Final Storage - Final, processed values arestored here for transfer to printer, tape, solidstate Storage Module or for

Pagina 80 - WIRE FULL BRIDGE

SECTION 14. INSTALLATION AND MAINTENANCE14-214.2 POWER REQUIREMENTSThe 21X operates at a nominal 12V DC. Below9.6 or above 16 volts the 21X does no

Pagina 81 - 7.13 LYSIMETER - 6 WIRE FULL

SECTION 14. INSTALLATION AND MAINTENANCE14-314.3 21X POWER SUPPLIESThe 21X is available with both alkaline batteries(21X) and lead acid batteries (2

Pagina 82

SECTION 14. INSTALLATION AND MAINTENANCE14-4TABLE 14.3-2. 21XL Battery and ACTransformer SpecificationsLead Acid BatteryBattery Type Gates #810-0011

Pagina 83 - SCIENTIFIC MODEL 101)

SECTION 14. INSTALLATION AND MAINTENANCE14-5FIGURE 14.6-1. Connecting Vehicle PowerSupply14.7 USE OF DIGITAL CONTROLPORTS FOR SWITCHING RELAYSEach

Pagina 84 - PROBE WITH 60 HZ REJECTION

SECTION 14. INSTALLATION AND MAINTENANCE14-6damage the datalogger. Campbell Scientific'sDC112 phone modem has spark gaps on thephone lines. A

Pagina 85

SECTION 14. INSTALLATION AND MAINTENANCE14-7The following procedures are for calibrating thevoltage reference and the clock. Other factorssuch as ra

Pagina 86

SECTION 14. INSTALLATION AND MAINTENANCE14-81. Remove the 21X battery base and unplugthe battery from the 21X. Remove the fourscrews holding the alu

Pagina 87 - 8.1 COMPUTATION OF RUNNING

SECTION 14. INSTALLATION AND MAINTENANCE14-9FIGURE 14.10-2. 21X CPU Board

Pagina 88 - 8.2 RAINFALL INTENSITY

SECTION 14. INSTALLATION AND MAINTENANCE14-10This is a blank page.

Pagina 89 - LOOP TO RUN AM416 MULTIPLEXER

A-1APPENDIX A. GLOSSARYASCII: Abbreviation for American StandardCode for Information Interchange(pronounced "askee"). A specific binaryco

Pagina 90

21X MICROLOGGER OVERVIEWOV-6Table 1.Execute every x sec.0.0125 < x < 6553Instructions are executedsequentially in the orderthey are entered in t

Pagina 91 - MULTIPLEXER TO STRIP CHART

APPENDIX A. GLOSSARYA-2INTERMEDIATE STORAGE: That portion ofmemory allocated for storing the results ofintermediate calculations necessary foroperat

Pagina 92

APPENDIX A. GLOSSARYA-3SIGNATURE: A number which is a function ofthe data and the sequence of data inmemory. It is derived using an algorithmwhich

Pagina 93 - STRIP CHART

APPENDIX A. GLOSSARYA-4This is a blank page.

Pagina 94 - PROGRAMMING EXAMPLE

B-1APPENDIX B. PROM SIGNATURES AND SOFTWARE OPTIONSThe 21X PROM signatures are viewed by entering the *B Mode and advancing to the appropriatewindow

Pagina 95

This is a blank page.

Pagina 96

C-1APPENDIX C. BINARY TELECOMMUNICATIONSC.1 TELECOMMUNICATIONSCOMMAND WITH BINARYRESPONSESCommand Description[no. of loc.]F BINARY DUMP - 21X sends,

Pagina 97 - EXAMPLES

APPENDIX C. BINARY TELECOMMUNICATIONSC-2previously executed; four time bytes, a userflags byte, four bytes for each input locationrequested in the J

Pagina 98

APPENDIX C. BINARY TELECOMMUNICATIONSC-3Another method that can be used as anestimate is to convert Data bytes 2 to 4 from along integer to floating

Pagina 99

APPENDIX C. BINARY TELECOMMUNICATIONSC-4to the telecommunications F command a 2 bytesignature is sent (see below).Representing the bits in the first

Pagina 100

APPENDIX C. BINARY TELECOMMUNICATIONSC-5BITS, 1ST BYTE,1ST PAIR DESCRIPTIONCDEF = 0111 Code designating 1st byte pair of four byte number.B Polarity

Pagina 101

21X MICROLOGGER OVERVIEWOV-721X. Work through the direct programmingexamples in this overview before using EDLOGand you will have the basics of 21X o

Pagina 102

APPENDIX C. BINARY TELECOMMUNICATIONSC-6This is a blank page.

Pagina 103

D-1APPENDIX D. ASCII TABLEAmerican Standard Code for Information InterchangeDecimal Values and Characters(X3.4-1968)Dec. Char. Dec. Char. Dec. Char.

Pagina 104

This is a blank page.

Pagina 105

E-1APPENDIX E. CHANGING RAM OR PROM CHIPSThe 21X has 8 sockets for memory chips. Five sockets hold 8K Random Access Memory (RAM) chipsand three hold

Pagina 106

APPENDIX E. CHANGING RAM OR PROM CHIPSE-2The earliest 21Xs were shipped with only two4K RAM chips. Current software does notcheck for this condition

Pagina 107

F-1APPENDIX F. DOCUMENTATION FOR SPECIAL SOFTWARE

Pagina 108

This is a blank page.

Pagina 109

15 SERIAL INPUT1. FUNCTIONInstruction 15 for the 21X is used to read datafrom an "intelligent" sensor that outputs serialASCII data.- Seria

Pagina 110

15 SERIAL INPUT2PARAMETER 3 Digital Control Port/Logic LevelThis parameter specifies which digital controlport is used and what the input logic level

Pagina 111

15 SERIAL INPUT33.2 21X/BAROMETER HOOK-UPBarometer lead wires are provided for twogeneral types of connections: TTL level outputto the 21X and an RS

Pagina 112

This is a blank page.

Pagina 113 - are not

21X MICROLOGGER OVERVIEWOV-8OV3.4 INSTRUCTION FORMATInstructions are identified by an instructionnumber. Each instruction has a number ofparameters

Pagina 114

15 SERIAL INPUT4TABLE 1. 21X/Barometer Connection Details

Pagina 115

15 SERIAL INPUT5TABLE 2. Number of Characters/Output and Memory Requirementsfor Various BarometerOutput ModesPARAMETER 5 The purpose of this paramet

Pagina 116

15 SERIAL INPUT601: P 15 Serial Input01: 1 Repetitions02: 1 Diff Input Chnl03: 1 Dig Ctrl Prt X=TTL/1X=RS23204: 9 Number Characters/Input05: 83 Delay

Pagina 117 - Parameters 6

1*D TAPE UPLOAD AND DOWNLOADFUNCTIONThis library option adds additional *D modecommands that allow datalogger programs tobe saved to and loaded from a

Pagina 118

This is a blank page.

Pagina 119

LT-1LIST OF TABLESPAGEOVERVIEWOV3-1 * Mode Summary ...

Pagina 120

LIST OF TABLESLT-2PAGE6. 9 PIN SERIAL INPUT/OUTPUT6.1-1 Pin Description ...

Pagina 121

LIST OF TABLESLT-3PAGE14. INSTALLATION AND MAINTENANCE14.2-1 Typical Current Drain for Common 21X Peripherals...

Pagina 122

LIST OF TABLESLT-4This is a blank page.

Pagina 123

LF-1LIST OF FIGURESPAGEOVERVIEWOV1-1 21X Micrologger ...

Pagina 124

21X MICROLOGGER OVERVIEWOV-9OV4.1 SAMPLE PROGRAM 1The 21X has a thermistor built into the inputpanel that measures the panel temperature andprovides

Pagina 125

LIST OF FIGURESLF-2PAGE13. 21X MEASUREMENTS13.1-1 Timing of Single-Ended Measurement...

Pagina 126

I-121X INDEX* Modes, see Modes1/X [Instruction 42] 10-2101 Thermistor ProbeProgramming example 7-11107 Thermistor Probe [Instruction 11] 9-5Prog

Pagina 127

21X INDEXI-2ClockCPU card circuitry calibration 14-7Setting/displaying time (*5 Mode) 1-2Programming example OV-14CM6/CM10 Tripod grounding protect

Pagina 128

21X INDEXI-3Redirecting data [Instruction 80] 11-5example 8-3Ring memory 2-1Flags 3-3Displaying and toggling 1-2Intermediate Processing Disable

Pagina 129

21X INDEXI-4Low Pass Filter [Instruction 58] 10-6Low resolution 2-2LP Filter [Instruction 58] 10-6Lysimeter, weighing 7-8MMaintenance and instal

Pagina 130

21X INDEXI-5Processing InstructionsDefinition OV-5Memory and execution times3-7

Pagina 131

21X INDEXI-6Program Control Instructions 12-1Definition OV-5Command code parameter 12-1Logical constructions 3-4Memory and execution times3-8Progr

Pagina 132

21X INDEXI-7Real Time [Instruction 77] 11-4Programming example OV-13Reference junctionCompensation 13-10Relays, Using digital ports for switching

Pagina 133

21X INDEXI-8Serial Input/OutputInterface details 6-1External peripherals 4-1Telecommunication 5-1Set Active Output Area [Instruction 80] 11-5Prog

Pagina 134

21X INDEXI-9Switching power 14-5System memory OV-3System status (*B Mode) 1-5TTables, program 1-1Tape Pointer (TPTR) 2-1Tape recorder 4-4Connec

Pagina 135

21X MICROLOGGER OVERVIEWOV-10Display ShowsKey (ID:Data) Explanation*0 :LOG 1 Exit Table 1, enter *0 mode to compile table andbegin measurements.*6 06:

Pagina 136

21X INDEXI-10VVapor Pressure From Wet-/Dry-BulbTemperatures [Instruction 57] 10-5Programming example 8-10Vehicle power supply 14-4Volts (SE) [Ins

Pagina 138

21X MICROLOGGER OVERVIEWOV-11Display ShowsKey (ID:Data) ExplanationA 02:0000 Enter repetition and advance to the secondparameter which specifies the f

Pagina 139

21X MICROLOGGER OVERVIEWOV-12will be inserted at that point in the table,advance through and enter the parameters.The Instruction that was at that poi

Pagina 140

21X MICROLOGGER OVERVIEWOV-13Parameter 3 specifies the channel on which tomake the first measurement. Parameter 6specifies the Input Storage location

Pagina 141

21X MICROLOGGER OVERVIEWOV-14Instruction Parameter Description(Loc.:Entry) (Par.#:Entry)04:P77 Output Time01:10 Store hour and minute.05:P71 Average01

Pagina 142

21X MICROLOGGER OVERVIEWOV-15Display ShowsKey (ID:Data) Explanation*5 00:21:32 Enter *5 mode. Clock running but not set correctly.A 05:89 Advance to Y

Pagina 143

21X MICROLOGGER OVERVIEWOV-16and exchanged for the one which isretrieved so that data collection cancontinue uninterrupted.2. Bring a storage device t

Pagina 144

21X MICROLOGGER OVERVIEWOV-17FIGURE OV5-1. Data Retrieval Hardware Options

Pagina 145

WARRANTY AND ASSISTANCEThe 21X MICROLOGGER is warranted by CAMPBELL SCIENTIFIC, INC. to be free from defects inmaterials and workmanship under normal

Pagina 146

21X MICROLOGGER OVERVIEWOV-18OV6. SPECIFICATIONS

Pagina 147

1-1SECTION 1. FUNCTIONAL MODES1.1 PROGRAM TABLES - *1, *2, AND *3MODESData acquisition and processing functions arecontrolled by instructions contai

Pagina 148

SECTION 1. FUNCTIONAL MODES1-21.1.3 TABLE PRIORITY/INTERRUPTSTable 1 execution has priority over Table 2. IfTable 2 is being executed when it is ti

Pagina 149 - SECTION 13. 21X MEASUREMENTS

SECTION 1. FUNCTIONAL MODES1-3TABLE 1.3-1. *6 Mode CommandsKey ActionA Advance to next location or enternew valueB Back-up to previous locationC Cha

Pagina 150

SECTION 1. FUNCTIONAL MODES1-4compilation. The display is not updated afterentering *0.When the *0, *B, or *D Mode is used to compile,all output port

Pagina 151 - LENGTH ON THE SIGNAL SETTLING

SECTION 1. FUNCTIONAL MODES1-51.5.2 *A MODEThe *A Mode is used to 1) determine thenumber of locations allocated to Input,Intermediate, and Final Sto

Pagina 152

SECTION 1. FUNCTIONAL MODES1-61.6 MEMORY TESTING AND SYSTEMSTATUS - *BThe *B Mode is used to 1) read the signature ofthe program memory and the soft

Pagina 153 - Error (degrees) =

SECTION 1. FUNCTIONAL MODES1-7TABLE 1.7-1. *C Mode Entries and CodesKey DisplayEntry ID: Data Description*C 12:0000 Enter current password. Ifcorrec

Pagina 154

SECTION 1. FUNCTIONAL MODES1-81.8.1 TRANSFER TO COMPUTER/PRINTERThis section describes commands 1 and 2(Table 1.8-1). TERM (PC208 Software)automati

Pagina 155

SECTION 1. FUNCTIONAL MODES1-94. A semicolon (;) tells the 21X to ignore therest of the line and can be used after anentry so that a comment can be a

Pagina 156

This is a blank page.

Pagina 157

SECTION 1. FUNCTIONAL MODES1-10This is a blank page.

Pagina 158 - MEASUREMENTS

2-1SECTION 2. INTERNAL DATA STORAGE2.1 FINAL STORAGE AREAS, OUTPUTARRAYS, AND MEMORY POINTERSFinal Storage is that portion of memory wherefinal, pro

Pagina 159

SECTION 2. INTERNAL DATA STORAGE2-2The Data Storage Pointer (DSP) is used todetermine where to store each new data point inthe Final Storage area. T

Pagina 160

SECTION 2. INTERNAL DATA STORAGE2-3The resolution of the low resolution format isreduced to 3 significant digits when the first (leftmost) digit is 7

Pagina 161

SECTION 2. INTERNAL DATA STORAGE2-4This is a blank page.

Pagina 162

3-1SECTION 3. INSTRUCTION SET BASICSThe instructions used to program the 21X are divided into 4 types: Input/Output (I/O), Processing,Output Processi

Pagina 163 - 13.5 BRIDGE RESISTANCE

SECTION 3. INSTRUCTION SET BASICS3-2counter. The loop counter is added to theindexed value to determine the actual inputlocation the instruction act

Pagina 164

SECTION 3. INSTRUCTION SET BASICS3-3location value is updated by an I/O Instruction.For example: Suppose a temperaturemeasurement is initiated by Ta

Pagina 165

SECTION 3. INSTRUCTION SET BASICS3-4set high. This flag is used to restrict samplingfor averages, totals, maxima, minima, etc., totimes when certain

Pagina 166

SECTION 3. INSTRUCTION SET BASICS3-5If Then/Else comparisons may be nested to formlogical AND or OR branching. Figure 3.8-2illustrates an AND constr

Pagina 167 - REQUIRING AC EXCITATION

i21X OPERATOR'S MANUALTABLE OF CONTENTSPAGEWARRANTY AND ASSISTANCESELECTED OPERATING DETAILS...

Pagina 168

SECTION 3. INSTRUCTION SET BASICS3-6nested 2 deep while the OR construction isnested 3 deep. Branching and loop nestingstarts at zero within each su

Pagina 169 - ENVIRONMENT

SECTION 3. INSTRUCTION SET BASICS3-7TABLE 3.9-2. Processing Instruction Memory and Execution TimesR = No. of Reps.MEMORYINPUT INTER. PROG.INSTRUCTIO

Pagina 170 - 14.2 POWER REQUIREMENTS

SECTION 3. INSTRUCTION SET BASICS3-8TABLE 3.9-3. Output Instruction Memory and Execution TimesR = No. of Reps.INSTRUCTION MEMORY EXECUTION TIME (ms)

Pagina 171 - 14.3 21X POWER SUPPLIES

SECTION 3. INSTRUCTION SET BASICS3-93.10 ERROR CODESThere are four types of errors flagged by the21X: Compile, Run Time, Editor, and *D Mode.When an

Pagina 172 - CONNECTIONS

SECTION 3. INSTRUCTION SET BASICS3-10This is a blank page.

Pagina 173 - 14.8 GROUNDING

4-1SECTION 4. EXTERNAL STORAGE PERIPHERALSExternal data storage devices are used to provide a data transfer medium that the user can carry fromthe te

Pagina 174 - 14.10 CALIBRATION PROCEDURES

SECTION 4. EXTERNAL STORAGE PERIPHERALS4-2Only one of the options 1x, 2x, or 30 may beused in a program. If using a SM64 StorageModule, output code

Pagina 175

SECTION 4. EXTERNAL STORAGE PERIPHERALS4-3TABLE 4.2-1. *8 Mode EntriesDisplayKey ID:DATA Description*8 08:00 Enter *8 Mode, key A toadvance to first

Pagina 176

SECTION 4. EXTERNAL STORAGE PERIPHERALS4-4When on-line Storage Module or printer transferis not enabled and the *9 Mode is used to dumpnew data, the

Pagina 177

SECTION 4. EXTERNAL STORAGE PERIPHERALS4-5POWER SUPPLYThe 21X's internal power supply will power therecorder during periods of data transfer, bu

Pagina 178

TABLE OF CONTENTSiiPROGRAMMINGPAGE1. FUNCTIONAL MODES1.1 Program Tables - *1, *2, and *3 Modes ...

Pagina 179 - APPENDIX A. GLOSSARY

SECTION 4. EXTERNAL STORAGE PERIPHERALS4-63. Insert the plugs on the free end of theSC92A or SC93A into the DC-IN and MIC(and Ear if SC93A) jacks on

Pagina 180

SECTION 4. EXTERNAL STORAGE PERIPHERALS4-71. Connect the Storage Module to the 21Xusing the SC12 cable.2. Enter the appropriate commands as listedin

Pagina 181

SECTION 4. EXTERNAL STORAGE PERIPHERALS4-8This is a blank page.

Pagina 182

5-1SECTION 5. TELECOMMUNICATIONSTelecommunications allows a computer to retrieve data directly from Final Storage and may beused to program the 21X a

Pagina 183

SECTION 5. TELECOMMUNICATIONS5-25. CR to datalogger means "execute".6. CRLF from datalogger means "executingcommand".7. ANY chara

Pagina 184

SECTION 5. TELECOMMUNICATIONS5-3[YR:DAY:HR:MM:SS]C RESET/SEND TIME - If time is entered the time is reset. If only 2 colons arein the time string, H

Pagina 185 - RESPONSES

SECTION 5. TELECOMMUNICATIONS5-4awaiting another command. So the user canstep back and forth between theTelecommunications Command State and theRemo

Pagina 186

6-1SECTION 6. 9 PIN SERIAL INPUT/OUTPUT6.1 PIN DESCRIPTIONAll external communication peripherals connectto the 21X through the 9-pin serial I/O conn

Pagina 187 - C.2 FINAL STORAGE FORMAT

SECTION 6. 9 PIN SERIAL INPUT/OUTPUT6-26.2 ENABLING PERIPHERALSSeveral peripherals may be connected in parallelto the 9-pin port. The 21X directs d

Pagina 188

SECTION 6. 9 PIN SERIAL INPUT/OUTPUT6-36.5.1 SC32A INTERFACEMost computers, terminals, and printers requirethe SC32A Optically Isolated RS232 Interf

Pagina 189 - C.3 GENERATION OF SIGNATURE

TABLE OF CONTENTSiiiPROGRAMMING EXAMPLESPAGE7. MEASUREMENT PROGRAMMING EXAMPLES7.1 Differential Voltage - LI200S Silicon Pyranometer ...

Pagina 190

SECTION 6. 9 PIN SERIAL INPUT/OUTPUT6-4If the computer is configured as DCE equipment(pin 2 is an input for RD), a null modem cable isrequired. See

Pagina 191 - APPENDIX D. ASCII TABLE

SECTION 6. 9 PIN SERIAL INPUT/OUTPUT6-5modem, especially when implemented bycomputer software.To overcome the limitations of half duplex, somecommuni

Pagina 192

SECTION 6. 9 PIN SERIAL INPUT/OUTPUT6-6This is a blank page.

Pagina 193 - E.2 INSTALLING NEW RAM CHIPS

7-1SECTION 7. MEASUREMENT PROGRAMMING EXAMPLESThis section gives some examples of Input Programming for common sensors used with the 21X. Theseexamp

Pagina 194 - E.3 CHANGING PROM CHIPS

SECTION 7. MEASUREMENT PROGRAMMING EXAMPLES7-2Figure 7.2-1. Since a single- endedmeasurement is referenced to the 21X ground,any voltage difference

Pagina 195

SECTION 7. MEASUREMENT PROGRAMMING EXAMPLES7-3FIGURE 7.4-1. Thermocouples with ExternalReference JunctionThe temperature of the 107 Probe is stored

Pagina 196

SECTION 7. MEASUREMENT PROGRAMMING EXAMPLES7-47.7 ANEMOMETER WITHPHOTOCHOPPER OUTPUTAn anemometer with a photochopper transducerproduces a pulsed ou

Pagina 197 - 15 SERIAL INPUT

SECTION 7. MEASUREMENT PROGRAMMING EXAMPLES7-5shortening switch life, a transient may beinduced in other wires, packaged with the raingauge leads, ea

Pagina 198 - THE AIR-DB-1A BAROMETER

SECTION 7. MEASUREMENT PROGRAMMING EXAMPLES7-6The fixed 100 ohm resistor must be thermallystable. Its precision is not important becausethe exact re

Pagina 199

SECTION 7. MEASUREMENT PROGRAMMING EXAMPLES7-7PROGRAM01: P7 3 Wire Half Bridge01: 1 Rep02: 3 50 mV slow Range03: 1 IN Chan04: 1 Excite all reps w/EXc

Pagina 200

TABLE OF CONTENTSivINSTALLATIONPAGE14. INSTALLATION AND MAINTENANCE14.1 Protection From the Environment ...

Pagina 201

SECTION 7. MEASUREMENT PROGRAMMING EXAMPLES7-8The relationship between temperature and PRTresistance is a slightly nonlinear one. Instruction16 comp

Pagina 202

SECTION 7. MEASUREMENT PROGRAMMING EXAMPLES7-97.13 LYSIMETER - 6 WIRE FULLBRIDGEWhen a long cable is required between a loadcell and the 21X, the re

Pagina 203 - *D TAPE UPLOAD AND DOWNLOAD

SECTION 7. MEASUREMENT PROGRAMMING EXAMPLES7-10are that it requires an extra differential channeland the added expense of a 6 wire cable. In thiscas

Pagina 204

SECTION 7. MEASUREMENT PROGRAMMING EXAMPLES7-11voltage to the excitation voltage; this output isconverted to gypsum block resistance withInstruction

Pagina 205 - LIST OF TABLES

SECTION 7. MEASUREMENT PROGRAMMING EXAMPLES7-12The manual for the 101 Probe gives thecoefficients of the 5th order polynomial used toconvert the outp

Pagina 206

SECTION 7. MEASUREMENT PROGRAMMING EXAMPLES7-13This measurement sequence should not beused to measure temperature on the 207temperature and RH probe.

Pagina 207

SECTION 7. MEASUREMENT PROGRAMMING EXAMPLES7-14This is a blank page.

Pagina 208

8-1SECTION 8. PROCESSING AND PROGRAM CONTROL EXAMPLESThe following examples are intended to illustrate the use of Processing and Program ControlInstr

Pagina 209 - LIST OF FIGURES

SECTION 8. PROCESSING AND PROGRAM CONTROL EXAMPLES8-204: P54 Block Move01: 9 No. of Values02: 12 First Source Loc Temp i-803: 1 Source Step04: 11 Fir

Pagina 210 - 13. 21X MEASUREMENTS

SECTION 8. PROCESSING AND PROGRAM CONTROL EXAMPLES8-3redirected to Final Storage Area 1, the time isoutput and the total is sampled.Input Location La

Pagina 211 - 21X INDEX

vSELECTED OPERATING DETAILS1. Storing Data - Data is stored in FinalStorage only by Output ProcessingInstructions and only when the Output Flagis set

Pagina 212

SECTION 8. PROCESSING AND PROGRAM CONTROL EXAMPLES8-4FIGURE 8.3-1. AM416 Wiring Diagram For Thermocouple and Soil Moisture Block MeasurementsEXAMPLE

Pagina 213

SECTION 8. PROCESSING AND PROGRAM CONTROL EXAMPLES8-513: P End Table 1* A Mode 10 Memory Allocation01: 35 Input Locations02: 64 Intermediate Location

Pagina 214

SECTION 8. PROCESSING AND PROGRAM CONTROL EXAMPLES8-6While of questionable value because of currentrequirements and strip chart reliability, somearch

Pagina 215

SECTION 8. PROCESSING AND PROGRAM CONTROL EXAMPLES8-702: 60 minute interval03: 10 Set high Flag 0 (output)11: P69 Wind Vector01: 1 Rep02: 180 Samples

Pagina 216

SECTION 8. PROCESSING AND PROGRAM CONTROL EXAMPLES8-814: P95 End15: P End Table 38.7 COVARIANCE CORRELATIONPROGRAMMING EXAMPLEThe example is a 2 lev

Pagina 217

SECTION 8. PROCESSING AND PROGRAM CONTROL EXAMPLES8-9TABLE 8.7-2. Example Outputs and Input Storage LocationsLEVEL 1 OUTPUTSMEANS LOC VARIANCES LOCC

Pagina 218

SECTION 8. PROCESSING AND PROGRAM CONTROL EXAMPLES8-10* 1 Table 1 Programs01: 1 Sec. Execution Interval01: P17 Panel Temperature01: 16 Loc [:PANL TEM

Pagina 219

SECTION 8. PROCESSING AND PROGRAM CONTROL EXAMPLES8-11TABLE 8.7-4. Thirty Minute Output From Example01 110 02 DAY 03 HRMIN 04 M(W1) 05 M(U1) 06 M(V1

Pagina 220

SECTION 8. PROCESSING AND PROGRAM CONTROL EXAMPLES8-12TABLE 8.8-1. FFT Real and Imaginary Results 0.25 and 1.25 Hz SignalBIN # Hz FFT Ri FFT Ii0 0

Pagina 221

SECTION 8. PROCESSING AND PROGRAM CONTROL EXAMPLES8-13TABLE 8.8-3. FFT Power Spectra Results0.25 and 1.25 Hz SignalBIN # Hz FFT PSi0 0 1.0859.22 0.2