User Guide
9
Figure 9. Hyperterminal Screen
Type the following command string that correlates to the datalogger and/or Baud rate
being used:
CR1000: AT&F0 S0=1 &D0 +IPR=6,0 V0 &K0 &W0 &Y0
CR10X: AT&F0 S0=1 &D0 +IPR=5,0 V0 &K0 &W0 &Y0
The appropriate command string will need to be used in both modems.
Press “Enter” once the string has been input. See Figures 10 and 11 for an example.
Figure 10. CR1000 AT Command String
The modem should return a 0 in the place of the first character (Figure 11).