Campbell COM310 Manuale Pagina 15

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 56
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 14
COM310 Voice Communications Modem
If Flags(mykey) Then
VoiceSpeak("ON",0)
Else
VoiceSpeak("OFF",0)
EndIf
VoiceSpeak("50MS PRESS POUND TO TOGGLE 50MS PRESS STAR TO RETURN", 0)
If VoiceKey(KeyTimeout) = POUND Then
flags(mykey) = NOT flags(mykey)
Else
ExitDo
EndIf
Loop
EndIf
Loop ' Port loop
EndSub
DataTable (Test,1,-1)
DataInterval (0,0,Sec,10)
Minimum (1,BatteryV,FP2,0,False)
Sample (1,PTemp,FP2)
Sample (1,TCvalue_F,FP2)
EndTable
' <<<<<<<<<<<<<<<<<< MEASUREMENT PROGRAM >>>>>>>>>>>>>>>>>>
BeginProg
Scan (1,Sec,3,0)
Battery (BatteryV)
PanelTemp (PTemp,250)
TCDiff (TCvalue_F,1,mV2_5C,7,TypeT,PTemp,True,0,250,1.8,32)
' Add measurement code here *******************
CallTable Test
NextScan
' <<< VOICE CALLBACK CODE that executes when alarm conditions are met >>>
SlowSequence
' Slow Sequence do loop forever possibly doing alarm call out
Const NUMPHONES = 3 ' 3 phone numbers to try
Const PHONE1 = "1112223333"
Const PHONE2 = "1112224444"
Const PHONE3 = "1112225555"
Dim i,Phones(NUMPHONES) As String
phones(1) = PHONE1
phones(2) = PHONE2
phones(3) = PHONE3
Alarm = FALSE
ArmAlarm = TRUE
Do ' Forever
Delay(1,1,sec)
If (TCvalue_F < 85) Then
ArmAlarm = TRUE
9
Vedere la pagina 14
1 2 ... 10 11 12 13 14 15 16 17 18 19 20 ... 55 56

Commenti su questo manuale

Nessun commento