CS526 ISFET pH Probe
Operating
Temperature: 10 to 40 °C
Water Pressure: 0 to 700 kPa (0 to 101.5 psi)
Power Requirement
Source: 5 Vdc
Load: 15 mA maximum
Output: TTL logic, 2400 bps
8 data bits, no parity, 1 stop bit
Maximum Cable Length: 100 m (328 ft)
Cable Type: Three-twisted pair, 24-AWG cable with
Santoprene
jacket
Sensor Material: PEEK
Weight
w/10-ft cable: 318 g (11.2 oz)
Dimensions
Length: 102 mm (4 in)
Diameter: 16 mm (0.63 in)
Certifications: ISO 9001
compliant
EMC standard IEC61326:2005
7. Operation
If you are programming your datalogger with Short Cut, skip Section 7.1,
Wiring
(p. 6), and Section 7.2, Datalogger Programming (p. 7). Short Cut does
this work for you. See Section 4, Quickstart
(p. 2), for a Short Cut tutorial.
7.1 Wiring
TABLE 7-1. Wiring
Wire Color Wire Label/Function Datalogger Connections
Red (see following
caution)
Power 5V 5V
Black Ground G
White Rx
Control Port
(odd numbered)
Green Tx
Control Port
(even numbered)
Clear Shield G