CR1000 Measurement and Control System
The CR1000 provides precision measurement capabilities in a rugged, battery-operated package. It consists of a
measurement and control module and a wiring panel. Standard operating range is -25° to +50°C; an optional extended
range of -55° to +85°C is available.
Features
2 Mbytes standard memory; 4 Mbytes optional memory
Program execution rate of up to 100 Hz
CS I/O and RS-232 serial ports
13-bit analog to digital conversions
16-bit H8S Renesas Microcontroller with 32-bit
internal CPU architecture
Temperature compensated real-time clock
Background system calibration for accurate mea-
surements over time and temperature changes
Single DAC used for excitation and measurements
to give ratio metric measurements
Gas Discharge Tube (GDT) protected inputs
Data values stored in tables with a time stamp and
record number
Battery-backed SRAM memory and clock ensuring
data, programs, and accurate time are maintained
while the CR1000 is disconnected from its main
power source
Measures intelligent serial sensors without using
an SDM-SIO4
Measurement and Control Module
The module measures sensors, drives direct commu-
nications and telecommunications, reduces data, con-
trols external devices, and stores data and programs in
on-board, non-volatile storage. The electronics are RF
shielded and glitch protected by the sealed, stainless
steel canister. A battery-backed clock assures accurate
timekeeping. The module can simultaneously provide
measurement and communication functions. The on-
board, BASIC-like programming language supports
data processing and analysis routines.
Wiring Panel
The CR1000WP is a black, anodized aluminum wiring
panel that is compatible with all CR1000 and CR1000-4M
modules. The wiring panel includes switchable 12 V,
redistributed analog grounds (dispersed among analog
channels rather than grouped), unpluggable terminal
block for 12 V connections, gas-tube spark gaps, and
12 V supply on pin 8 to power our COM-series phone
modems and other peripherals. The control module
easily disconnects from the wiring panel allowing field
replacement without rewiring the sensors. A description
of the wiring panel's input/output channels follows.
{
Removable Power
Terminal—simplifies
connection to external
power supply.
Input/Output Connections
Individually configured for
ratiometric resistive bridge,
thermocouple, switch closure,
high frequency pulse, low-level
ac, serial sensors, and more.
Peripheral Port—one 40-pin port interfaces with
the CFM100 CompactFlash® module, which allows
data to be stored on a CompactFlash card.
CS I/O Port—connects to
data transfer and storage
peripherals such as phone,
RF, short-haul, and multi-
drop modems.
Computer RS-232
provides a 9-pin electri-
cally isolated DCE port.
Vedere la pagina 1